Buy our

Black conductive fabric and Copper conductive fabric

special conductive fabrics

Series

Standard covering of gaskets

Standard all our EMI shielding gaskets can be supplied with an Amucor (aluminium alloy) cover or with an electrically conductive textile cover. However, for some applications it is necessary to cover the gasket with a special conductive cover.

Alternatively, we can also supply our EMI shielding gaskets with a copper conductive fabric (copper colour) or a copper nickel conductive fabric (black).

Copper / Nickel conductive fabric
Properties
(23 °C, 50% RH)
Value
(nominal)
Unit International standard
(HEC test method)
Mass per unit area 70 g/m2 ISO 9073-1
Thickness 0,08 mm ISO 9073-2
Fabric Density 260    
Shielding effectiveness 60 dB From
10 MHz To
3 GHz
 
Surface Resistivity < 0,05    
Fire Point 250 °C    
Composition Basic Polyester
Copper and Nickel
Copper conductive fabric
Properties
(23 °C, 50% RH)
Value
(nominal)
Unit International standard
(HEC test method)
Mass per unit area 75 g/m2 ISO 9073-1
Thickness 0,08 mm ISO 9073-2
Fabric Density 230    
Tensile stength 51 N/cm ISO 9073-3
Shielding effectiveness >60 dB From
10 MHz To
3 GHz
 
Surface Resistivity < 0,05    
Fire Point 250 °C    
Composition Basic Polyester
Copper
Happy to help
Allowed maximum size is 20 MiB. You can upload multiple files