Shielded Rooms by Holland Shielding

Faraday cage and shielded room engineering, installation and verification
Faraday Cages & Shielded Rooms

EMI/RFI, EMP and EMSEC Protection for Rooms, Equipment and Environments

Faraday cages and shielded rooms reduce electromagnetic interference and unwanted signals entering or leaving a controlled environment. They are used for EMC testing, secure communication, research, defense, critical infrastructure and other applications where reliable electromagnetic shielding is required.

Holland Shielding Systems BV designs, manufactures, installs and verifies prefabricated, modular and custom-built shielding solutions. From engineering to final acceptance testing, our specialists can support every stage of the project.

Complete Shielding Solutions

Faraday cages, shielded rooms and shielding enclosures engineered as complete systems.

Modular Construction

Prefabricated and custom-built shielding systems adapted to the available space and technical requirements.

Engineering and Installation

Engineering, manufacturing, installation and shielding verification coordinated as one project.

Why Shield a Room?

When Is a Faraday Cage or Shielded Room Required?

A shielded environment can be used when electromagnetic interference, unwanted emissions or sensitive technical processes need to be controlled.

Protect Sensitive Equipment

Reduce external electromagnetic interference that could affect electronics, measurements and communication systems.

Control Unwanted Emissions

Help reduce electromagnetic emissions leaving the shielded environment and reaching nearby equipment or spaces.

Create a Controlled Environment

Create controlled electromagnetic conditions for EMC testing, research, secure communication and technical work.


Shielded Room Solutions

Our Faraday Cage and Shielded Room Solutions

The suitable shielding solution depends on the frequency range, required attenuation, dimensions, access points, ventilation, cable entries and installation environment.

Complete Faraday cages and shielded rooms for EMI RFI and TEMPEST applications
Complete Shielded Rooms

Prefabricated Faraday cages, EMI-shielded chambers, TEMPEST rooms and custom shielding constructions.

Discover →

Flexible Faraday tents and temporary EMI shielded environments
Flexible Shielding Solutions

Faraday tents and temporary shielded environments for mobile testing, measurements and short-term projects.

Discover →

Mobile EMI and RFI shielded boxes for reducing wireless communication
EMI/RFI Shielded Boxes

Mobile Faraday cages for transporting or testing equipment where wireless communication needs to be reduced.

Discover →

Specialized magnetic TEMPEST and EMP shielded room constructions
Specialized Shielding

Magnetic shielding, architectural shielding, anechoic chambers, TEMPEST-related environments and welded EMP constructions.

Discover →


Project Process

Typical Shielded Room Project Process

Design, production, installation and verification are coordinated as one complete shielding project.

1. Define

Review the application, dimensions, frequency range, required attenuation and installation environment.

2. Engineer

Design the room, access points, filters, ventilation and conductive connections.

3. Produce and Install

Manufacture, prepare and install the shielding components according to the agreed design.

4. Verify

Measure the completed room using the agreed test method, frequency range and acceptance criteria.


Construction Options

Choose the Right Shielded Room Construction

The suitable construction depends on the available space, installation method, frequency range, required attenuation and future modification requirements.

Prefabricated modular Faraday cage and shielded room
Modular Construction

Prefabricated and Modular Faraday Cages

Conductive panels are mechanically and electrically connected to create a continuous shielded enclosure.

  • Suitable for new and existing buildings
  • Available in standard and custom dimensions
  • Easier transport, installation and future modification
  • Can include doors, windows, filters and ventilation

Discuss a modular construction →

Custom-built Faraday cage and shielded room construction
Project-Specific Construction

Custom-Built Shielded Rooms

A project-specific construction follows the shape of an existing room, building or technical installation.

  • Suitable for complex room shapes
  • Adapted to existing structures and technical spaces
  • Project-specific access points and penetrations
  • Engineered as one complete shielding system

Discuss a custom construction →


Power signal and data line filters for shielded rooms

Shielded Doors

EMI shielded doors for shielded rooms, secure facilities and EMC test environments.

Discover →

power, signal & data line filters

EMI Filters

Power line filters that reduce electromagnetic interference entering or leaving shielded enclosures.

Discover →

Honeycomb shielded ventilation panels for Faraday cages

Ventilation Panels

Honeycomb ventilation panels that combine airflow with effective EMI shielding.

Discover →

Waveguides and cable entries for shielded rooms

Cable Entries

Shielded cable entry systems for power, signal and data connections without compromising shielding performance.

Discover →

gaskets solutions from holland shielding in a shielded room

Gaskets

EMI/RFI conductive gaskets for sealing joints, doors and removable panels.

Discover →

Conductive seams and electrical connections in a shielded room

RF absorbers

Microwave absorber materials for reducing reflections and improving EMC performance.

Discover →

shielded windows and transparency solutions

Shielded Visibility 

High-performance shielded windows that maintain visibility while reducing electromagnetic leakage.

Discover →

waveguides solutions for a shielded room

Waveguides

Waveguide penetrations for ventilation, pipes and cables while preserving shielding effectiveness.

Discover →

holland shielding products, systems, services and support

Voxofaag noise generator

Controlled broadband noise generation for EMC testing and shielding verification.

Discover →

holland shielding products, systems, services and support

Low Emmission LED panel

EMI-optimized LED lighting designed for shielded rooms and EMC-sensitive environments.

Discover →

holland shielding products, systems, services and support

Shielding Effectiveness Monitoring System

Continuous monitoring of shielding performance for critical installations and secure facilities.

Discover →

holland shielding products, systems, services and support

Our offer

From standard products to fully customized shielding solutions, engineering and project support.

Discover →

A Single Weak Point Can Affect the Complete Room

An untreated opening, unfiltered cable, poorly connected seam or incorrectly integrated door can create an electromagnetic leakage path. We therefore assess the complete shielded environment rather than only the wall or panel material.


Applications

Typical Faraday Cage Applications

Faraday cages and shielded rooms are used across industries where electromagnetic interference, information security or reliable testing must be controlled.

Defense and Aerospace

TEMPEST shielded environments for military systems, aerospace electronics, secure communications and EMP-related applications.

Government and Security

TEMPEST secure rooms for government buildings, communication systems, intelligence environments and public safety applications.

Data Centers and Infrastructure

TEMPEST shielding for data centers, telecom systems, utilities, energy installations and other critical infrastructure.

Research and Laboratories

Controlled environments for universities, EMC laboratories, research institutes and sensitive scientific measurements.

Industrial and Manufacturing

Shielded spaces for industrial automation, machinery, control cabinets, production equipment and EMC testing.

Medical and Healthcare

Shielded environments for MRI systems, hospitals, laboratories, medical devices and interference-sensitive equipment.


Testing & Verification

Shielding Performance Verification

The shielding performance of a completed Faraday cage or shielded room can be verified by measurement. The frequency range, test positions, measurement method and acceptance criteria should be agreed before testing.

A measurement report or shielding effectiveness certificate can be provided when required.

Testing & troubleshooting →

Shielding performance measurement and verification of a Faraday cage

Frequently Asked Questions

Faraday Cage and Shielded Room FAQ

What Shielding Performance Can a Faraday Cage Achieve?

The achievable shielding performance depends on the construction, materials, frequency range, doors, filters, ventilation, cable entries and conductive connections. The required performance should be defined before the room is designed.


Can an Existing Room Be Converted Into a Shielded Room?

Existing rooms can often be converted. The floor, walls, ceiling, doors, windows, ventilation and technical penetrations must first be reviewed.


Can Ventilation and Cooling Be Added?

Shielded ventilation panels, air-conditioning penetrations and cooling systems can be integrated while controlling electromagnetic leakage paths.


Can Power, Data and Signal Cables Enter the Room?

Power, data and signal connections can be integrated using suitable filters, waveguides, feedthroughs and shielded cable-entry systems.


Can the Completed Room Be Measured?

The completed room can be measured using an agreed frequency range, test method and acceptance criteria. A measurement report can be provided when required.


Information Required for a Shielded Room Quotation

Please provide as much of the following information as possible. Our engineers can help determine missing project details.

1. Room and Construction
  • Room dimensions and drawings
  • New-build or existing location
  • Floor, wall and ceiling construction
  • Available installation space
  • Required access and maintenance space
2. Required Components
  • Shielded doors and windows
  • Power and signal line filters
  • Ventilation and cooling
  • Cable entries and waveguides
  • Grounding and bonding requirements
3. Performance Requirements
  • Required frequency range
  • Required shielding attenuation
  • Applicable standard or test method
  • Intended room application
  • Required verification or certification
Shielded room project by Holland Shielding Systems

Need a Faraday cage or shielded room?

Send us your drawings, dimensions, performance requirements and project description. Our engineers will review your application and recommend a suitable shielding solution.

Contact our shielded room engineers →
More results