Check our

Honeycomb ventilation panels

honeycomb ventilation panels icon 1

Series

Please note: Specify the outer dimension in mm.
Please note: Specify the outer dimension in mm
Allowed maximum size is 64 MiB. You can upload multiple files

Honeycomb vents are used to shield openings for ventilation or acoustic/visual contact. We can make these vents according to your drawing within a few days, or you can use our standard range from stock.

We can supply Honeycomb vents with frames, pre-drilled with fasteners, or with flow-drilled thread holes. The standard material is aluminium which can be given a nickel finish (or any other finish you choose).

If high shielding levels are required, the use of cross-cell honeycombs is recommended. These are constructed from multiple sections of 6.35 mm or 12.7 mm or 26 mm thick honeycombs within a single frame. The shielding performance will improve as airflow is decreased, but not eliminated.

For military applications we make a heavy hot-dip galvanized mild-steel version. Please contact us for more information.

Honeycombs are also frequently used as flow straighteners to create a laminar flow.


Standard and cross cell versions
honeycomb ventilation panels corss cell versions
Benefits
  • Lightweight
  • High shielding performance
  • Low air-flow resistance
  • Reduction of turbulence

Options
  • Cross-cell honeycomb for extra high shielding performance
  • Slant honeycomb 30°, 45°, 60° for outdoor rainproof applications
  • 45° degrees is the most common implementation
    Please note, slant honeycombs are available on request
  • Polyurethane filter for dust protection
  • Kick plate for mechanical protection
  • Stainless steel, mild steel or brass versions
  • Cell sizes 1.6mm, 3.2mm, 6.4mm, 9.5mm, 12.7mm, or 19mm (standard 3.2mm)
  • Gaskets for firm connections Amucor shielding gasket or Knitted wire mesh gasket

Approximately 95% of the honeycomb vents we produce are made to customer specifications.


Shielding performance (dB)
Frequency Field Single-layer 6.35 mm thick honeycomb material Cross-cell 6.35 mm thick honeycomb material Single-layer 12.7 mm thick honeycomb material Cross-cell 54 mm thick honeycomb material
Frames B, C, D, G, L Frame H Frames E, F Frame K
100MHz E 80 105 100 110
500MHz P 55 93 55 95
2GHz P 52 94 96 98
10GHz P 61 82 80 90
These values were measured under laboratory conditions, Honeycomb 80 x 80 mm and with proper gasket material used. In other situations, results may differ. Please read our Guarantee.

honeycomb ventilation panels Mild steel ventilation panels for EMP

Honeycomb ventilation panels Mild steel ventilation panels for EMP

honeycomb ventilation panels frame H example

Panels made in different sizes and amounts made according to your drawing

honeycomb ventilation panels

Honeycomb ventilation frame panel type h


Airflow characteristics
9500 series air flow characteristic

Please note: These values are measured under laboratory conditions. Results may vary in other situations; please read our Guarantee.

Shielding effectiveness
9500 series honeycomb ventilation panels

Mounting options
honeycomb ventilation panels mounting option 1 Option 1 : Through hole/bolt
honeycomb ventilation panels mounting option 2 Option 2: Flow-drilled tap/thread

Frame Options

Cross-cell honeycombs
honeycomb ventilation panels Cross-cell honeycombs frame a
honeycomb ventilation panels Cross-cell honeycombs frame k
honeycomb ventilation panels Cross-cell honeycombs frame h honeycomb ventilation panels Cross-cell honeycombs frame h

For frame H we recommend contacting us with your drawing. When designing the drawing for frame H please keep in mind to use a hole distance of minimal 75mm.


Single-layer honeycombs
honeycomb ventilation panels Cross-cell honeycombs frame b
honeycomb ventilation panels Cross-cell honeycombs frame c
honeycomb ventilation panels Cross-cell honeycombs frame e
honeycomb ventilation panels Cross-cell honeycombs frame f

honeycomb ventilation panels Cross-cell honeycombs frame l

Gasket material

Our 9500 series framed Honeycomb ventilation panels are generally supplied with a 6800 series Amucor gasket.

This is an EMC gasket with an aluminum alloy. Suitable for most applications. However, due to galvanic corrosion for some applications, the Honeycombs can also be supplied with a 1200 series Metal knit gasket.

Honeycomb copper version

Optional on request is a copper version of the honeycombs available in 6.35 and 12.7 mm thickness.

honeycomb ventilation panels copper version

Standard dimensions

Our Honeycomb ventilation panels are usually custom made for our client. However, some common dimensions are in stock. In the standard dimensions table below some common types of Honeycomb ventilation panels are specified to illustrate the required information. Hole diameter P is standard 3.5 mm, with other dimensions possible on request. Also available with screw apertures or inserts.

honeycomb ventilation panel technical drawing
Holes
Outer dimensions Mounting holes horizontal Mounting holes vertical
A B No D E Holes F G
150 75 2 40 70 1 37.5 -
100 100 1 50 - 1 50 -
200 100 3 20 80 1 50 -
125 125 2 20 85 1 62.5 -
250 125 3 30 95 1 62.5 -
150 150 2 25 100 2 25 100
300 150 4 30 80 2 25 100
175 175 2 40 95 2 40 95
350 175 4 40 90 2 40 95
200 200 3 40 60 3 40 60
400 200 5 30 85 3 20 80
250 250 3 30 95 3 30 95
300 300 4 30 80 4 30 80
600 300 7 30 90 4 30 80