High-performance EMI/RFI absorber sheets

high performance emi rfi absorber sheets icon 1

Series

Specify the width in mm.
Specify the length in mm.

The high-performance EMI (electromagnetic interference) absorber and noise suppression series developed by Holland Shielding Systems B.V. can eliminate noise effectively. This product is made with magnetic metal powder. Through the distributed and mixed process, there is a Microwave absorbing sheet made of rubber sheets. As use of wide frequency band increases, this products absorbs and controls unnecessary electronic microwaves (noise). You can solve EMC/EMI problems by attaching EM absorber and noise suppression sheets simply on (part of) the noise sources.

The high performance EMI absorber sheet series is designed for applications where high noise suppression is needed in a broad frequency range. Examples are applications in the construction of medical and military devices.

Advantages
  • Perfect suppression of radiation noise.
  • High electrical resistance (1x109 Ω)
  • Flexible and easy to handle/apply with single-side adhesive, even on a rounded side.
  • Can be manufactured in many shapes, sizes and thickness according to CAD drawing

High-performance EMI/RFI absorber sheets construction
 
Part number Unit 5790-ES11 5790-ES12 5790-ES31 5790-ES45 5790-ES46 5790-ES47 5790-ES48
Feature   Wide band Wide band Wide band, High permeability Standard Wide band Wide band Wide band, High permeability
Structure   Single layer
Frequency range   10 MHz to 6 GHz
Permeability   55 ± 5 (@13.56MHz) 60 ± 5 (@13.56MHz) 130 ± 5 (@5MHz) 25 ± 5 (@5MHz) 70 ± 5 (@3MHz) 80 ± 5 (@3MHz) 95 ± 5 (@3MHz)
Operating temp. °C -30 ∼ +80
Density g/cm3 3.7 ± 0.3 3.7 ± 0.3 3.7 ± 0.3 3.5 ± 0.3 3.5 ± 0.3 3.5 ± 0.3 3.7 ± 0.3
Surface resistance Ω/sq >1 x 106
Standard thickness mm 0.1 mm (others on request)
Standard dimensions mm 200x300 (others on request)
Adhesion gf/25mm Min 1,000
Environmental issues   RoHS compliant

Please note: These ferrite tiles are very thin, which can save more space for chamber installation. The tiles are non-flammable and they can be fully suitable for high-power test chambers. Ferrite tiles can be screwed directly on to the shielded housing; installation is very easy. Even after many years the effect of the ferrite tiles still will not be degraded.


Permeability & Reflection loss
High-performance EMI/RFI absorber sheets permability and insertion loss

5790-ES11 Permeability

High-performance EMI/RFI absorber sheets permability and insertion loss

5790-ES11 Return loss

High-performance EMI/RFI absorber sheets permability and insertion loss

5790-ES12 Permeability

High-performance EMI/RFI absorber sheets permability and insertion loss

5790-ES12 Return loss

High-performance EMI/RFI absorber sheets permability and insertion loss

5790-ES31 Permeability

High-performance EMI/RFI absorber sheets permability and insertion loss

5790-ES31 Return loss

High-performance EMI/RFI absorber sheets permability and insertion loss

5790-ES45 Permeability

High-performance EMI/RFI absorber sheets permability and insertion loss

5790-ES45 Return loss

High-performance EMI/RFI absorber sheets permability and insertion loss

5790-ES46 Permeability

High-performance EMI/RFI absorber sheets permability and insertion loss

5790-ES46 Return loss

High-performance EMI/RFI absorber sheets permability and insertion loss

5790-ES47 Permeability

High-performance EMI/RFI absorber sheets permability and insertion loss

5790-ES47 Return loss

High-performance EMI/RFI absorber sheets permability and insertion loss

5790-ES48 Permeability

High-performance EMI/RFI absorber sheets permability and insertion loss

5790-ES48 Return loss

Contact
More results