Linefilter HGN 375

 

Features

The HGN-375 protects electronic equipment from common and differential mode line interference in the range of 10KHz up to 30MHz. This “combi-unit” is equipped with IEC connector, fuse holder for one or two 5 x 20 mm fuses, 2 pole on/off switch and fully enclosed metal housing. These filters are also available for Medical equipment with low leakage current. HGN-375 series filters are high performance filters and have been designed to bring various medical equipments into compliance with EN55011 and FCC Part 15J, Class B conducted emissions limits.


Applications

Computer & networking equipment, Measuring & control equipment, Data processing equipment, Laboratory instruments, Switching power supplies, other electronic equipment.


Technical Data
Operating voltage 250V / 50Hz
120V / 60Hz
Rated current, 40°C 1A / 2A / 4A / 6A
Leakage current <0,5mA / 250 VAC
Temperature range -25°C - +85°C
Test voltage (VDE 0565) 1,8kV / 50Hz - 2s
 
 Type / Ordering-No.  Nominal current at 40°C CX2 [μF]
CY[pF]
L[mH]
Remarks
 HGN 365-1-FX
             -2-FX
             -4-FX
             -6-FX
1A
2A
4A
6A
0,068 + 0,033 + 0,1
0,068 + 0,033 + 0,1
0,068 + 0,033 + 0,1
0,068 + 0,033 + 0,1
 2 x 2200
2 x 2200
2 x 2200
2 x 2200
 2 x 10,3
2 x  4,6
2 x  1,2
2 x  0,8
X=L: 2 Fuses 5 x 20 mm
 Medical version    
 HGN 365-1M-FX
             -2M-FX
             -4M-FX
             -6M-FX
1A
2A
4A
6A
0,068 + 0,033 + 0,1
0,068 + 0,033 + 0,1
0,068 + 0,033 + 0,1
0,068 + 0,033 + 0,1
 -
-
-
-
 2 x 10,3
2 x 4,6
2 x 1,2
2 x 0,8


Linefilter HGN 375
Circuit
Dimensions Dimensions
Attenuation in 50 Ohm-
50 Ohm according to CISPR

 

 