Linefilter HGN 369

 

Features

The HGN-369 power entry modules are used in applications having the ON/OFF switch on front side but main input at the rear side. This series features an IEC Connector, voltage selector for four different voltages (100V, 120V, 220V, 240V), fuse holder for European 5 x 20mm fuse. The filter is enclosed in a metal housing to ensure maximum protection from common-mode and differential-mode interferences. These filters are also available for Medical equipment with low leakage current to comply with UL 544 & UL2601.


Applications

Computer & networking equipment, Measuring & control equipment, Data processing equipment, Laboratory instruments, Switching power supplies, other electronic equipment.


Technical Data
Operating voltage 250V / 50Hz
120V / 60Hz
Rated current, 40°C 1A / 2A / 3A / 4A / 6A
Leakage current <0,5mA / 250 VAC
Temperature range -25°C - +85°C
Test voltage (VDE 0565) 1,8kV / 50Hz - 2s
 

Type / Ordering-No.  Nominal current at 40°C CX2 [μF]
CY[pF]
L[mH]
Remarks
 HGN 365-1X
             -2X
             -3X
             -3X
             -6X
1A
2A
3A
4A
6A
0,033
0,033
0,033
0,033
0,033
 2 x 2200
2 x 2200
2 x 2200
2 x 2200
2 x 2200
2 x 10,3
2 x 4,6
2 x 2,5
2 x 1,2
2 x 0,8
X=E: 1 Fuse 5 x 20 mm