2600 - Circular series for 0.8 - 9 mm gap

Circular fingerstrips are used for grounding and EMI shielding in high-frequency equipment and for forming large-diameter rings of round contacts. Circular fingerstrips are used to solve grounding en EMI-shielding problems where round contacts and a dynamic range are required.

Items in bold type are stock items.

Circular finger 2601

Circular fingerstrips 2601-01, 2601-03, 2601-04, 2601-05, 2601-07, 2601-08 Technical drawing, for electrical contact and EMI shielding
2601-01, 2601-03, 2601-04, 2601-05, 2601-07, 2601-08 Technical drawing

Circular fingerstrips 2601-02, 2601-06 Technical drawing, for electrical contact and EMI shielding
2601-02, 2601-06 Technical drawing

Circular fingerstrips 2601-09 Technical drawing, for electrical contact and EMI shielding
2601-9 Technical drawing

Circular fingerstrips 2601-10 Technical drawing, for electrical contact and EMI shielding
2601-10 Technical drawing
Hole diameter Ø 3.5
2600 series Circular fingerstrips
2600 Series Circular fingerstrips
2600 series Circular fingerstrips
2600 Series Circular fingerstrips for forming large diamter round contacts rings
2600 series Circular fingerstrips for forming electrically conductive contact rings with large diameters
Part numberABCFGHMaterial thicknessCompression
2601-01 8.7 1.0 3.2 406 1.5 1.0 0.10 mm  
2601-02 9.5 1.2 3.2 500 1.5 1.0 0.10 mm  
2601-03 9.7 1.3 1.6 406 1.9 1.3 0.16 mm  
2601-04 13.5 1.3 5.5 406 1.9 1.3 0.16 mm  
2601-05 14.0 1.1 6.5 499 4.0 3.0 0.20 mm  
2601-06 14.1 0.8 5.5 500 2.0 1.5 0.15 mm  
2601-07 18.5 1.1 6.5 499 4.0 3.0 0.20 mm  
2601-08 19.1 3.1 12.7 406 4.8 3.6 0.13 mm  
2601-09 22.6 3.0 14.9 406 4.8 3.6 0.13 mm 25% 12 kg/m
50% 55 kg/m
2601-10 30.0 3.2 9.0 503 4.0 3.0 0.5 mm  

Material: Beryllium-copper


Circular finger 2602

Circular fingerstrips 2602-01 till 2602-04 Technical drawing, for electrical contact and EMI shielding
2602-01 to 2602-04 Technical drawing

Circular fingerstrips 2602-05 Technical drawing, for electrical contact and EMI shielding
2602-05 Technical drawing
Hole diameter Ø 3.5
 
Part numberABCDEFGHMaterial thickness
2602-01 9.2 1.2  3.2 2.5 3.6 500 1.5 1.0 0.10 mm
2602-02 13.8 1.3  6.5 2.7 8.0 499 4.0 3.0 0.20 mm
2602-03 13.9 0.8  5.5 3.0 6.0 500 2.0 1.5 0.15 mm
2602-04 18.3 1.3  6.5 3.9 8.0 499 4.0 3.0 0.20 mm
2602-05 27.9 3.2 9.0 9.0 10.0 502 4.0 3.0 0.5 mm

Material: Beryllium-copper


Circular finger 2603

Circular fingerstrips 2603-01 Technical drawing, for electrical contact and EMI shielding
2603-01 Technical drawing

Circular fingerstrips 2603-02 Technical drawing, for electrical contact and EMI shielding
2603-02 Technical drawing

Circular fingerstrips 2603-03 and 2603-04 Technical drawing, for electrical contact and EMI shielding
2603-03 and 2603-04 Technical drawing
Part numberABCDFGHMaterial thickness
2603-01 5.5 1.2 3.9 2.1 500 2.0 1.5 0.10 mm
2603-02 7.8 0.8 6.0 2.5 500 1.5 1.0 0.15 mm
2603-03 11.0 1.1 8.0 3.8 499 4.0 3.0 0.20 mm
2603-04 15.0 1.1 8.0 4.6 499 4.0 3.0 0.20 mm

Material: Beryllium-copper


Circular finger 2604

Circular fingerstrips 2604-01 Technical drawing, for electrical contact and EMI shielding
2604-01 Technical drawing

Circular fingerstrips 2604-02 till 2604-06 Technical drawing, for electrical contact and EMI shielding
2604-02 to 2604-06 Technical drawing

Circular fingerstrips 2604-07 Technical drawing, for electrical contact and EMI shielding
2604-07 Technical drawing
Part numberABCDFGHMaterial thicknessCompression
2604-01 4.8 0.8 4.1 2.3 406 1.5 1.0 0.13 mm 25% 10 kg/m
50% 15 kg/m
2604-02 6.6 - 5.8 2.8 406 1.9 1.3 0.15 mm 25% 13 kg/m
50% 25 kg/m
2604-03 7.0 0.9 6.5 2.8 500 2.0 1.5 0.15 mm  
2604-04 9.2 1.3 7.7 4.5 500 4.0 3.0 0.20 mm  
2604-05 11.2 - 8.1 4.1 406 2.4 1.6 0.25 mm 25% 22 kg/m
50% 70 kg/m
2604-06 11.5 1.3 9.8 4.7 500 4.0 3.0 0.20 mm  
2604-07 4.0 0.8 4.2 2.6 406 1.5 1.0 0.10 mm  

Material: Beryllium-copper


Circular finger 2605

Circular fingerstrips 2605-01 till 2605-03 Technical drawing, for electrical contact and EMI shielding
2605-01 to 2605-03 Technical drawing

Circular fingerstrips 2605-04 Technical drawing, for electrical contact and EMI shielding
2605-04 Technical drawing
Part numberABCDFGHMaterial thickness
2605-01 7.0 0.8 5.5 4.9 500 2.0 1.5 0.15 mm
2605-02 9.5 1.1 6.4 7.0 500 4.0 3.0 0.20 mm
2605-03 12.0 1.1 8.4 8.0 500 4.0 3.0 0.20 mm
2605-04 4.1 1.2 4.6 2.4 500 1.5 1.0 0.10 mm
Material: Beryllium-copper

Circular finger 2606

Circular fingerstrips 2606-01 Technical drawing, for electrical contact and EMI shielding
2606-01 Technical drawing

Circular fingerstrips 2606-02 Technical drawing, for electrical contact and EMI shielding
2606-02 Technical drawing

Circular fingerstrips 2606-03 Technical drawing, for electrical contact and EMI shielding
2606-03 Technical drawing

Circular fingerstrips 2606-04 Technical drawing, for electrical contact and EMI shielding
2606-04 Technical drawing

Circular fingerstrips 2606-05 Technical drawing, for electrical contact and EMI shielding
2606-05 Technical drawing

Circular fingerstrips 2606-06 Technical drawing, for electrical contact and EMI shielding
2606-06 Technical drawing

Circular fingerstrips 2606-07 Technical drawing, for electrical contact and EMI shielding
2606-07 Technical drawing
Part number A B C D F G H Material thickness
2606-01 19.5 5.8 16.0 0.13 406 4.8 3.6  
2606-02 22.6 2.3 16.0 0.13 406 4.8 3.6  
2606-03 22.6 3.3 16.0 0.13 406 4.8 3.6  
2606-04 23.4 2.3 16.0 0.13 406 4.8 3.6  
2606-05 23.4 2.3 16.0 0.13 406 4.8 3.6  
2606-06 23.4 2.3 16.0 0.13 406 4.8 3.6 0.13 mm
2606-07 19.5 3.1 15.8 0.13 406 4.8 3.6  

Circular finger 2607

Circular fingerstrips 2607-01 Technical drawing, for electrical contact and EMI shielding
2607-01 Technical drawing

Circular fingerstrips 2607-02 Technical drawing, for electrical contact and EMI shielding
2607-02 Technical drawing
Part number A B C D F G H Material thickness Compression
2607-01 9.1 0.75 4.1 0.13 406 2.4 1.6 0.13 mm 25% 22 kg/m
50% 103 kg/m
2607-02 9.1 0.9 4.1 0.13 406 2.5 1.7 0.13 mm  

The fingers of Part numbers 2607-01 and 2607-02 are turned outwards by approximately 30 °.

Part numbers 2607-01 and 2607-02 are supplied with an adhesive strip for easy mounting - see the red mark in the technical drawing above.

Material: Beryllium-copper

 

Circular fingerstrips, round contacts used for grounding and EMI shielding Circular fingerstrips, round contacts used for grounding and EMI shielding Holland Shielding Systems B.V. Holland Shielding Systems B.V.
Rated 4.4/5 based on 5 customer reviews
In stock
Product description: Cost-effective long-term EMI/RFI performance. The BeCu fingerstrips/fingerstock are available in a variety of surface finishes.

To get a quotation for Circular fingersrips within 24 hours fill in the form below.

Part number
Specify the part number that you need from the table above
* Note: The red blocks are required

Shielding pouch

IECLF339

Power line filter with integrated 2-pole switch, 2 fuses and a 2-way voltage selector

P

Small pin (for 1500 series)

1550

Conductive Foil PCB shielding Gaskets

8050

Power line filters for shielded cabinet

7800

Ultra soft twin shield